G SERIES - GLOB TYPE HYDRAULIC CONTROL VALVE G-PRV SERIES - PRESSURE REDUCING CONTROL VALVE G-QRV SERIES - PRESSURE RELIEF HYDRAULIC CONTROL VALVE G-FLV SERIES - FLOAT LEVEL CONTROL VALVE G-EL / 2W SERIES - SOLENOID CONTROL VALVE G-EL / 3W SERIES - SOLENOID CONTROL VALVE G-EFL SERIES - ELECTRICAL FLOAT CONTROL VALVE G-PSV SERIES - PRESSURE SUSTAINING CONTROL VALVE G-PRSV SERIES - PRESSURE REDUCING AND SUSTAINING CONTROL VALVE G-PREL SERIES - PRESSURE REDUCING SOLENOID CONTROL VALVE G-ECV SERIES - ELECTRONIC CONTROL VALVE G-DKV SERIES - FLOW CONTROL VALVES G-PKV SERIES - PUMP CONTROL VALVE G-REV SERIES - SURGE ANTICIPATING CONTROL VALVE G-CV SERIES - HYDRAULIC CHECKVALVE G-LCV SERIES - LIFT TYPE CHECKVALVE DQR / DIRECT ACTING RELIEF CONTROL VALVE DLG-EL / ELECTRIC ACTIVATION DELUGE ALARM VALVE DLG-P / PNEUMATIC ACTUATION DELUGE (DRY) ALARM VALVE DLG-ELP / ELECTRO-PNEUMATIC ACTIVATION DELUGE ALARM VALVE (PRE-ACTION)

IRRIGATION

D SERIES - DIAPHRAGM OPERATORS HYDRAULIC CONTROL VALVES D-MV SERIES - MANUEL HYDRAULIC CONTROL VALVE D-ELV SERIES - SELONOID CONTROL VALVE D-PRV SERIES - PRESSURE REDUCING CONTROL VALVE D-QRV SERIES - PRESSURE RELIEF HYDRAULIC CONTROL VALVE D-PKV SEERIES - PUMP CONTROL VALVE D-PREL SERIES - PRESSURE REDUCING SELENOID CONTROL VALVE D-FLV SERIES - FLOAT CONTROL VALVE D-PSV SERIES - PRESSURE SUSTAINING CONTROL VALVE D-PRSV SERIES - PRESSURE REDUCING AND SUSTAINING CONTROL VALVE

FIRE FIGHTING

MECHANICAL VALVES

KNIFE GATE VALVE SURFACE BOXES CHECK VALVE (CLASS 150) CHECK VALVE (DISC TYPE) CHECK VALVE (SPRING TYPE) CHECK VALVE (GLOBE TYPE) CHECK VALVE (BALL) CHECK VALVE (WAFER TYPE) CHECK VALVE (CLASS 125) CHECH VALVE (SWING TYPE) CHECK VALVE (VERTICAL TYPE) DISMANTLING JOINT FOOT VALVES SAFETY VALVES GLOBE VALVES GLOBE VALVE (CLASS 150) GLOBE VALVE (CLASS 125) BUTTERFLY VALVE (LUG TYPE) BUTTERFLY VALVES (DOUBLE FLANGE) BUTTERFLY VALVE (WAFER TYPE) STRAINER BASKET BALL VALVES (CLASS 150-300) BALL VALVE (PN10) BALL VALVE (PN16) BALL VALVE (THREADED) STRAINER (Y TYPE) IRRIGATION HYDRANT (DOUBLE OUTPUT) IRRIGATION HYDRANT (SINGLE OUTPUT) GATE VALVE RISING STEM (CLASS 150) GATE VALVE RISING STEM (CLASS 125) GATE VALVES (PN10) GATE VALVE RISING STEM (PN16) GATE VALVE RESILIENT SEATED (PN10) GATE VALVE RESILIENT SEATED (PN16) GATE VALVE (PN 16) GATE VALVE (WITH INDICATOR) GATE VALGE RISING STEM (PN10) FLOAT VALVE (ANGLE TYPE) FLOAT VALVE (FLAT TYPE) TILTING CHECK VALVE AIR VALVES FIRE HYDRANT (SHORT TYPE) FIRE HYDRANT (OVER GROUND)

G-LCV SERIES - LIFT TYPE CHECKVALVE

G-LCV SERIES - LIFT TYPE CHECKVALVE

PRODUCT DESCRIPTION

The lift type checkvalves are mechanical checkvalves that don’t have any control equipment on it. They protect the pumps with preventing adverse flow to the pumps at the pump lift stations while the pumps’ stopping instance. They open up themselves when the entrance pressure force exceeds the spring force in the checkvalve. When the pump flow ends they close up impermeable with the effect of the spring force.

PROPERTIES

The lift type checkvalves prevent adverse flow to the pumps like the other checkvalves.
The lift type checkvalves work mechanically because of not having any control equipment. Thus, they can create surges in the system.
The lift type checkvalves create less surge with closing up smoothly compared with the other mechanical swing type checkvalves.
The lift type checkvalves are closed up fully impermeable in the network.
The valve works with the line pressure entirely hydraulic without needing any extra energy.
The valve’s maintenance is quite easy and cheap because of its design is globe type.
The valve works safely even vertical and horizontal mountings.

OPERATING MANUAL

Mount the valve according to the arrow placed on the valve that shows the flow direction.
Mounting isolation valves (gate, butterfly or ball etc.) at the entrance direction for shutting-off the water in the line are recommended to ease the maintenance of the valve.
For the valve’s efficient working it is recommended to use an air relief valve before the valve.
Evacuate the water in the valve’s actuator to the atmosphere to prevent freezing in winter.
If the valve’s impermeability is not provided, check the clack in the valve. If the clack gasket damaged, change it with the new one.




1. Pump
2. Isolation Valve
3. Strainer
4.Lift Type Check Valve
5.Relief Control Valve
6.Air Valve
7.Pressure Gauge